Product Page

TOMZN TOB1-63H 4-Pole 63A AC Breaker | microsolution.com.pk

 4,800

[yith_wcwl_add_to_wishlist]

Need some help?

Contact Us

Product Ships in

2-3-business Days

Payment Methods:

TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan 

 

Do you need complete, four-pole protection for your three-phase electrical system in Pakistan? We bring you the ultimate solution: the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan. This heavy-duty device actively disconnects all four poles simultaneously when it detects an overload or short circuit. You no longer worry about phase imbalances damaging your industrial equipment or commercial machinery.

The TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan handles up to 63 Amperes of continuous current across all three phases and neutral. It responds within milliseconds when any phase exceeds safe limits. You protect your entire three-phase installation from dangerous fault conditions. Pakistani factories, workshops, and large homes experience frequent voltage fluctuations, and this 4-pole breaker handles them professionally.

Why do electrical contractors across Lahore, Faisalabad, and Multan recommend this specific model? The answer lies in its robust construction and reliable tripping accuracy. The TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan works perfectly on both 230V single-phase and 400V three-phase systems. It accepts both 50Hz and 60Hz frequencies, making it compatible with all Pakistani power grids and backup generators. Many local 4-pole breakers fail under load, but this TOMZN model performs consistently.

We understand that quality matters when protecting expensive industrial equipment. The TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan delivers international-grade protection at a competitive price point. You save money by avoiding costly motor burnouts, transformer damage, and production downtime. Factory owners appreciate the 4-pole isolation that completely disconnects the neutral wire for maximum safety. Electricians love the clear ON/OFF status indicators on each pole. Students learning three-phase systems study this breaker's standardized design.

The C-type tripping characteristic makes this breaker perfect for inductive loads. The TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan handles the high inrush currents of motors, compressors, and pumps without nuisance tripping. It trips only during genuine overloads or short circuits. You enjoy uninterrupted production while staying fully protected.

Moreover, the housing uses high-grade flame-retardant thermoplastic. The TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan maintains its structural integrity even during heavy fault conditions. You install it in main distribution panels, sub-panels, or motor control centers with complete confidence.

Stop using three-pole breakers that leave the neutral wire unprotected. Switch to the complete isolation of the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan today. Order now and secure your three-phase system properly.

2️⃣ Key Features 

  1. Disconnects all four poles (3 phases + neutral) simultaneously for complete circuit isolation.

  2. Protects your three-phase motors, compressors, and pumps from dangerous overloads instantly.

  3. Handles up to 63 Amperes of continuous current on each phase without overheating.

  4. Trips within milliseconds when it detects a short circuit or overload condition.

  5. Works reliably on both 230V single-phase and 400V three-phase electrical systems.

  6. Operates on both 50Hz and 60Hz frequencies, matching Pakistani grid and generator power.

  7. Features C-type tripping characteristic that handles motor starting currents perfectly.

  8. Mounts easily on standard 35mm DIN rail inside any industrial distribution board.

  9. Saves your expensive three-phase equipment from phase loss and imbalance damage.

  10. Resets quickly with a simple lever flick after fixing the underlying fault.

  11. Indicates clearly on each pole when tripped with visible mechanical flags.

  12. Prevents fire hazards by disconnecting power before wires overheat and melt.

  13. Cools itself efficiently using advanced arc quenching technology for each pole.

  14. Simplifies wiring with large, easy-to-access tunnel-type terminal screws.

  15. Saves panel space by combining four poles in a single compact housing.

  16. Provides clear ON/OFF markings on each pole to prevent operator confusion.

  17. Resists dust and humidity with a sealed, flame-retardant thermoplastic housing.

  18. Delivers consistent performance for over 10,000 mechanical switching operations.

  19. Reduces downtime in your factory by isolating only the faulty three-phase circuit.

  20. Meets international IEC 60898-1 safety standards for global quality assurance.

3️⃣ Advanced Features 

  1. Incorporates four independent thermal bimetal strips that accurately monitor each phase separately.

  2. Employs four magnetic blowout coils that extinguish arcs faster than standard breakers.

  3. Utilizes silver alloy contact tips that resist welding under repeated short-circuit conditions.

  4. Features a common trip mechanism that disconnects all poles when any single phase faults.

  5. Delivers energy limitation class 3, reducing total let-through energy to protect downstream devices.

  6. Includes self-cleaning wiping contacts that remove oxidation each time you toggle the switch.

  7. Provides automatic temperature compensation for consistent tripping across all seasons.

  8. Achieves double-break contact technology per pole for faster current interruption speed.

  9. Maintains contact resistance below 5 milliohms per pole for minimal power loss.

  10. Offers mechanical endurance exceeding 20,000 switching operations without failure.

  11. Houses high-grade copper internal busbars for efficient current conduction across phases.

  12. Features captive terminal screws that never fall out during installation.

  13. Uses transparent terminal shields for finger protection and visual inspection.

  14. Supports pollution degree 3 rating for dusty industrial environments.

  15. Integrates micro-gap arc splitting chambers with multiple metal plates per pole.

  16. Delivers consistent performance at altitudes up to 2000 meters above sea level.

  17. Provides thermal memory feature that remembers previous overload conditions.

  18. Employs a sealed magnetic yoke to prevent external magnetic interference.

  19. Includes visual wear indicators that show contact degradation over time per pole.

  20. Aligns with global RoHS environmental standards for hazardous substance control.

4️⃣ Frequently Asked Questions

Q1: What exactly does the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan protect?
Answer: It protects three-phase circuits including motors, compressors, pumps, and main distribution panels. The 4-pole design disconnects neutral as well.

Q2: Can I install the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan myself?
Answer: Only a licensed industrial electrician should install 4-pole breakers. The DIN rail design makes professional installation straightforward.

Q3: Why choose a 4-pole breaker instead of a 3-pole for my TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan?
Answer: A 4-pole breaker disconnects the neutral wire also. This provides complete isolation and improves safety during maintenance.

Q4: Does the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan work with generators?
Answer: Yes, it works perfectly on both 50Hz grid power and 60Hz generator power. The breaker accepts both frequencies seamlessly.

Q5: How do I reset the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan after a trip?
Answer: Move each pole lever fully to OFF, then push all levers back to ON simultaneously. The breaker resets when you clear the fault.

Q6: What does "C Type" mean on the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan?
Answer: C Type indicates the tripping curve. It tolerates motor starting surges (5-10 times rated current) without nuisance tripping.

Q7: Does the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan require separate neutral protection?
Answer: No, the 4-pole design includes neutral protection. The breaker disconnects neutral along with all three phases simultaneously.

Q8: Where can I buy an original TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan?
Answer: You purchase genuine TOMZN 4-pole breakers from our authorized distributors across Punjab or through our verified online store.

Q9: How long does the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan typically last?
Answer: Under normal industrial use, it lasts over 15 years or 10,000 switching operations, whichever comes first.

Q10: Will this TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan fit my existing panel?
Answer: Yes, it fits any standard distribution board with a 35mm DIN rail. It directly replaces most older 4-pole breakers.

5️⃣ Where It Can Be Used 

  1. Factory Main Panels: Protect the entire three-phase electrical supply to manufacturing facilities.

  2. Three-Phase Motor Circuits: Secure industrial motors, conveyor systems, and production line equipment.

  3. Commercial HVAC Systems: Protect large air conditioning units and chiller plants in office buildings.

  4. Agricultural Tube Wells: Guard three-phase water pumps and irrigation systems on farms.

  5. Elevator & Lift Circuits: Secure passenger and goods elevators in commercial buildings.

  6. Industrial Compressors: Protect air compressors and pneumatic systems in workshops.

  7. Three-Phase Generator Outputs: Guard backup generator feeds to building distribution panels.

  8. Large Apartment Complexes: Protect main incoming supplies for multi-story residential buildings.

  9. Hospital Equipment Panels: Secure critical three-phase medical equipment and backup systems.

  10. Food Processing Units: Protect mixing machines, conveyors, and packaging equipment.

6️⃣ How to Use 

Follow these steps to install your TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan correctly. Always prioritize safety.

Step 1: Turn Off Main Power
Switch off and lock out the upstream main breaker. Use a voltage tester to confirm no electricity flows on any phase or neutral. Never work on live three-phase systems.

Step 2: Prepare the Distribution Board
Open your three-phase distribution board cover. Locate a free slot on the 35mm DIN rail. Hook the bottom clip of the TOMZN 4P MCB onto the rail. Push the top section firmly until you hear a click.

Step 3: Connect Incoming Wires
Identify the incoming L1, L2, L3 (phases) and Neutral wires. Connect each to the top terminals marked 1, 3, 5, and N (or 1, 2, 3, N). Tighten all terminal screws securely.

Step 4: Connect Outgoing Wires
Take the outgoing wires running to your load. Connect L1, L2, L3, and Neutral to the bottom terminals (2, 4, 6, and N). Double-check each connection for tightness.

Step 5: Verify Phase Rotation
Before connecting sensitive equipment, verify correct phase sequence (L1, L2, L3) using a phase rotation meter. Incorrect sequence damages three-phase motors.

Step 6: Label the Circuit
Write the equipment or area name on your distribution board label. Note that this 4-pole breaker controls all three phases and neutral.

Safety Tips

  • Use 16mm² or larger copper wire for 63A circuits.

  • Never operate the breaker without the cover installed.

  • Keep the breaker dry and free from dust.

Maintenance Guidance
Test each pole every six months. Toggle all levers together to ensure smooth operation. Check all terminal screws annually using a torque screwdriver. If you notice burning smells or discoloration on any pole, replace the entire 4-pole breaker immediately.

Restoring Power After a Trip
When the breaker trips, first inspect all connected equipment for faults. Move all four levers fully to OFF, then push them back to ON together. If it trips again, call an industrial electrician immediately.

7️⃣ Advantages 

  1. Complete Isolation: You disconnect the neutral wire along with all three phases for maximum safety.

  2. Three-Phase Protection: You secure motors and industrial equipment from phase imbalances and overloads.

  3. High Current Capacity: You handle up to 63A per phase for heavy machinery and main panels.

  4. Motor-Friendly C-Curve: You tolerate starting surges without nuisance tripping.

  5. Universal Frequency Compatibility: You use the same breaker on 50Hz grid or 60Hz generator power.

  6. Space Efficient Design: You protect four poles in a single compact housing, saving panel space.

  7. Quick Fault Recovery: You restore three-phase power instantly after clearing the fault.

  8. Professional Grade Safety: You meet industrial standards for worker protection during maintenance.

  9. Long Operational Life: You enjoy over 15 years of reliable service in demanding environments.

  10. Cost-Effective Protection: You prevent expensive motor burnouts and production downtime.

8️⃣ Disadvantages 

  1. Professional Installation Required: You cannot install this 4-pole breaker without a licensed industrial electrician.

  2. Higher Cost Than 3-Pole: You pay more for the additional neutral pole compared to standard 3-pole breakers.

  3. Requires Neutral Access: You need a neutral wire at the distribution board location for proper 4-pole operation.

  4. Larger Footprint: You occupy more DIN rail space than a 3-pole breaker with separate neutral bar.

  5. Single Breaking Capacity: You avoid using this where fault currents exceed 6,000 amperes.

  6. Manual Operation Only: You cannot remotely monitor or reset this breaker without additional modules.

  7. No RCD Functionality: You still need separate four-pole RCDs for earth leakage protection.

  8. Not for Single-Phase Only: You waste capacity using this expensive 4-pole breaker on single-phase systems.

  9. Limited Local Stock: You may find this 4-pole model only through online or industrial suppliers.

  10. Heavier Weight: You need a sturdy DIN rail that supports the extra weight of four poles.

9️⃣ City-Wise Sales Coverage in Punjab 

You purchase the TOMZN TOB1-63H4P AC MCB C Type 230/400V~ 50HZ/60HZ 63A Mini Circuit Breaker in Pakistan from our authorized industrial network across all major Punjab cities. We deliver quickly to Lahore, Faisalabad, Rawalpindi, Multan, Gujranwala, Sialkot, Bahawalpur, Sargodha, Rahim Yar Khan, Sheikhupura, Jhang, Dera Ghazi Khan, Gujrat, Okara, Kasur, Sahiwal, Khanewal, Chiniot, Pakpattan, and Vehari. Contact our industrial sales team or order online for doorstep delivery across Punjab.

Buy TOMZN TOB1-63H 4P AC MCB C Type 63A in Pakistan. 4-pole protection for three-phase systems. 230V/400V, 50/60Hz. Fast Punjab delivery.

TOMZN TOB1-63H, 4 pole MCB Pakistan, 63A miniature circuit breaker, C type MCB 63A, three phase breaker Pakistan, TOMZN 4P breaker Lahore, 400V MCB Pakistan, 50Hz 60Hz circuit breaker, buy TOMZN industrial MCB, 4 pole breaker for motor, TOMZN Pakistan distributor, industrial MCB Punjab, 63A three phase protection, TOMZN TOB1 price Pakistan, main panel breaker Pakistan